Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
Arch Dis Child Fetal Neonatal Ed ; 108(3): 217-223, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36424125

RESUMO

OBJECTIVE: The effect of prophylactic surfactant nebulisation (SN) is unclear. We aimed to determine whether prophylactic SN improves early lung aeration. DESIGN: Parallel, randomised clinical trial, conducted between March 2021 and January 2022. SETTING: Delivery room (DR) of a tertiary neonatal centre in Zurich, Switzerland. PATIENTS: Preterm infants between 26 0/7 and 31 6/7 weeks gestation INTERVENTIONS: Infants were randomised to receive positive distending pressure alone or positive distending pressure and additional SN (200 mg/kg; poractant alfa) using a customised vibrating membrane nebuliser. SN commenced with the first application of a face mask immediately after birth. MAIN OUTCOME MEASURES: Primary outcome was the difference in end-expiratory lung impedance from birth to 30 min after birth (∆EELI30min). EELI correlates well with functional residual capacity. Secondary outcomes included physiological and clinical outcomes. RESULTS: Data from 35 infants were collected, and primary outcome data were analysed from 32 infants (n=16/group). Primary outcome was not different between intervention and control group (median (IQR): 25 (7-62) vs 10 (0-26) AU/kg, p=0.21). ∆EELI was slightly higher in the intervention group at 6 and 12 hours after birth, particularly in the central areas of the lung. There were no differences in cardiorespiratory and clinical parameters. Two adverse events were noted in the intervention group. CONCLUSIONS: Prophylactic SN in the DR did not significantly affect ∆EELI30min and showed only minimal effects on lung physiology. Prophylactic SN in the DR was feasible. There were no differences in clinical outcomes. TRIAL REGISTRATION NUMBER: NCT04315636.


Assuntos
Recém-Nascido Prematuro , Surfactantes Pulmonares , Lactente , Recém-Nascido , Humanos , Tensoativos , Pressão Positiva Contínua nas Vias Aéreas , Pulmão
3.
Arch Dis Child Fetal Neonatal Ed ; 108(2): 170-175, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36038255

RESUMO

OBJECTIVE: Mechanisms of non-invasive high-frequency oscillatory ventilation (nHFOV) in preterm infants are unclear. We aimed to compare lung volume changes during apnoeas in preterm infants on nHFOV and nasal continuous positive airway pressure (nCPAP). METHODS: Analysis of electrical impedance tomography (EIT) data from a randomised crossover trial comparing nHFOV with nCPAP in preterm infants at 26-34 weeks postmenstrual age. EIT data were screened by two reviewers to identify apnoeas ≥10 s. End-expiratory lung impedance (EELI) and tidal volumes (VT) were calculated before and after apnoeas. Oxygen saturation (SpO2) and heart rate (HR) were extracted for 60 s after apnoeas. RESULTS: In 30 preterm infants, 213 apnoeas were identified. During apnoeas, oscillatory volumes were detectable during nHFOV. EELI decreased significantly during apnoeas (∆EELI nCPAP: -8.0 (-11.9 to -4.1) AU/kg, p<0.001; ∆EELI nHFOV: -3.4 (-6.5 to -0.3), p=0.03) but recovered over the first five breaths after apnoeas. Compared with before apnoeas, VT was increased for the first breath after apnoeas during nCPAP (∆VT: 7.5 (3.1 to 11.2) AU/kg, p=0.001). Falls in SpO2 and HR after apnoeas were greater during nCPAP than nHFOV (mean difference (95% CI): SpO2: 3.6% (2.7 to 4.6), p<0.001; HR: 15.9 bpm (13.4 to 18.5), p<0.001). CONCLUSION: Apnoeas were characterised by a significant decrease in EELI which was regained over the first breaths after apnoeas, partly mediated by a larger VT. Apnoeas were followed by a considerable drop in SpO2 and HR, particularly during nCPAP, leading to longer episodes of hypoxemia during nCPAP. Transmitted oscillations during nHFOV may explain these benefits. TRIAL REGISTRATION NUMBER: ACTRN12616001516471.


Assuntos
Apneia , Recém-Nascido Prematuro , Síndrome do Desconforto Respiratório do Recém-Nascido , Humanos , Lactente , Recém-Nascido , Pressão Positiva Contínua nas Vias Aéreas/métodos , Ventilação com Pressão Positiva Intermitente/métodos , Volume de Ventilação Pulmonar , Estudos Cross-Over
4.
BMC Pediatr ; 22(1): 464, 2022 08 03.
Artigo em Inglês | MEDLINE | ID: mdl-35918685

RESUMO

BACKGROUND: Post-mortem imaging has been suggested as an alternative to conventional autopsy in the prenatal and postnatal periods. Noninvasive autopsies do not provide tissue for histological examination, which may limit their clinical value, especially when infection-related morbidity and mortality are suspected. METHODS: We performed a prospective, multicentre, cross-sectional study to compare the diagnostic performance of post-mortem magnetic resonance imaging with computed tomography-guided biopsy (Virtopsy®) with that of conventional autopsy in foetuses and infants. Cases referred for conventional autopsy were eligible for enrolment. After post-mortem imaging using a computed tomography scanner and a magnetic resonance imaging unit, computed tomography-guided tissue sampling was performed. Virtopsy results were compared with conventional autopsy in determining the likely final cause of death and major pathologies. The primary outcome was the proportion of cases for which the same cause of death was determined by both methods. Secondary outcomes included the proportion of false positive and false negative major pathological lesions detected by virtopsy and the proportion of computed tomography-guided biopsies that were adequate for histological examination. RESULTS: Overall, 101 cases (84 fetuses, 17 infants) were included. Virtopsy and autopsy identified the same cause of death in 91 cases (90.1%, 95% CI 82.7 to 94.5). The sensitivity and specificity of virtopsy for determining the cause of death were 96.6% (95% CI 90.6 to 98.8) and 41.7% (95% CI 19.3 to 68.0), respectively. In 32 cases (31.7%, 95% CI 23.4 to 41.3), major pathological findings remained undetected by virtopsy, and in 45 cases (44.6%, 95% CI 35.2 to 54.3), abnormalities were diagnosed by virtopsy but not confirmed by autopsy. Computed tomography-guided tissue sampling was adequate for pathological comments in 506 of 956 biopsies (52.7%) and added important diagnostic value in five of 30 cases (16.1%) with an unclear cause of death before autopsy compared with postmortem imaging alone. In 19 of 20 infective deaths (95%), biopsies revealed infection-related tissue changes. Infection was confirmed by placental examination in all fetal cases. CONCLUSIONS: Virtopsy demonstrated a high concordance with conventional autopsy for the detection of cause of death but was less accurate for the evaluation of major pathologies. Computed tomography-guided biopsy had limited additional diagnostic value. TRIAL REGISTRATION: ClinicalTrials.gov (NCT01888380).


Assuntos
Placenta , Tomografia Computadorizada por Raios X , Biópsia , Estudos Transversais , Feminino , Feto/diagnóstico por imagem , Humanos , Lactente , Imageamento por Ressonância Magnética/métodos , Gravidez , Estudos Prospectivos , Tomografia Computadorizada por Raios X/métodos
5.
Arch Dis Child Fetal Neonatal Ed ; 107(5): 551-557, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35101993

RESUMO

INTRODUCTION: Non-invasive high-frequency oscillatory ventilation (nHFOV) is an extension of nasal continuous positive airway pressure (nCPAP) support in neonates. We aimed to compare global and regional distribution of lung volumes during nHFOV versus nCPAP. METHODS: In 30 preterm infants enrolled in a randomised crossover trial comparing nHFOV with nCPAP, electrical impedance tomography data were recorded in prone position. For each mode of respiratory support, four episodes of artefact-free tidal ventilation, each comprising 30 consecutive breaths, were extracted. Tidal volumes (VT) in 36 horizontal slices, indicators of ventilation homogeneity and end-expiratory lung impedance (EELI) for the whole lung and for four horizontal regions of interest (non-gravity-dependent to gravity-dependent; EELINGD, EELImidNGD, EELImidGD, EELIGD) were compared between nHFOV and nCPAP. Aeration homogeneity ratio (AHR) was determined by dividing aeration in non-gravity-dependent parts of the lung through gravity-dependent regions. MAIN RESULTS: Overall, 228 recordings were analysed. Relative VT was greater in all but the six most gravity-dependent lung slices during nCPAP (all p<0.05). Indicators of ventilation homogeneity were similar between nHFOV and nCPAP (all p>0.05). Aeration was increased during nHFOV (mean difference (95% CI)=0.4 (0.2 to 0.6) arbitrary units per kilogram (AU/kg), p=0.013), mainly due to an increase in non-gravity-dependent regions of the lung (∆EELINGD=6.9 (0.0 to 13.8) AU/kg, p=0.028; ∆EELImidNGD=6.8 (1.2 to 12.4) AU/kg, p=0.009). Aeration was more homogeneous during nHFOV compared with nCPAP (mean difference (95% CI) in AHR=0.01 (0.00 to 0.02), p=0.0014). CONCLUSION: Although regional ventilation was similar between nHFOV and nCPAP, end-expiratory lung volume was higher and aeration homogeneity was slightly improved during nHFOV. The aeration difference was greatest in non-gravity dependent regions, possibly due to the oscillatory pressure waveform. The clinical importance of these findings is still unclear.


Assuntos
Ventilação de Alta Frequência , Ventilação não Invasiva , Pressão Positiva Contínua nas Vias Aéreas/métodos , Ventilação de Alta Frequência/métodos , Humanos , Lactente , Recém-Nascido , Recém-Nascido Prematuro , Ventilação com Pressão Positiva Intermitente/métodos , Ventilação não Invasiva/métodos , Volume de Ventilação Pulmonar
6.
Arch Dis Child Fetal Neonatal Ed ; 107(5): 508-512, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34862191

RESUMO

OBJECTIVE: We sought to determine the effect of stimulation during positive pressure ventilation (PPV) on the number of spontaneous breaths, exhaled tidal volume (VTe), mask leak and obstruction. DESIGN: Secondary analysis of a prospective, randomised trial comparing two face masks. SETTING: Single-centre delivery room study. PATIENTS: Newborn infants ≥34 weeks' gestation at birth. METHODS: Resuscitations were video recorded. Tactile stimulations during PPV were noted and the timing, duration and surface area of applied stimulus were recorded. Respiratory flow waveforms were evaluated to determine the number of spontaneous breaths, VTe, leak and obstruction. Variables were recorded throughout each tactile stimulation episode and compared with those recorded in the same time period immediately before stimulation. RESULTS: Twenty of 40 infants received tactile stimulation during PPV and we recorded 57 stimulations during PPV. During stimulation, the number of spontaneous breaths increased (median difference (IQR): 1 breath (0-3); padj<0.001) and VTe increased (0.5 mL/kg (-0.5 to 1.7), padj=0.028), whereas mask leak (0% (-20 to 1), padj=0.12) and percentage of obstructed inflations (0% (0-0), padj=0.14) did not change, compared with the period immediately prior to stimulation. Increased duration of stimulation (padj<0.001) and surface area of applied stimulus (padj=0.026) were associated with a larger increase in spontaneous breaths in response to tactile stimulation. CONCLUSIONS: Tactile stimulation during PPV was associated with an increase in the number of spontaneous breaths compared with immediately before stimulation without a change in mask leak and obstruction. These data inform the discussion on continuing stimulation during PPV in term infants. TRIAL REGISTRATION NUMBER: Australian and New Zealand Clinical Trial Registry (ACTRN12616000768493).


Assuntos
Recém-Nascido Prematuro , Máscaras , Austrália , Humanos , Recém-Nascido , Recém-Nascido Prematuro/fisiologia , Respiração com Pressão Positiva , Estudos Prospectivos , Volume de Ventilação Pulmonar/fisiologia
7.
Arch Dis Child Fetal Neonatal Ed ; 106(4): 381-385, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33298407

RESUMO

OBJECTIVE: Application of a face mask may induce apnoea and bradycardia, possibly via the trigeminocardiac reflex (TCR). We aimed to describe rates of apnoea and bradycardia in term and late-preterm infants following facemask application during neonatal stabilisation and compare the effects of first facemask application with subsequent applications. DESIGN: Subgroup analysis of a prospective, randomised trial comparing two face masks. SETTING: Single-centre study in the delivery room PATIENTS: Infants>34 weeks gestational age at birth METHODS: Resuscitations were video recorded. Airway flow and pressure were measured using a flow sensor. The effect of first and subsequent facemask applications on spontaneously breathing infants were noted. When available, flow waveforms as well as heart rate (HR) were assessed 20 s before and 30 s after each facemask application. RESULTS: In total, 128 facemask applications were evaluated. In eleven percent of facemask applications infants stopped breathing. The first application was associated with a higher rate of apnoea than subsequent applications (29% vs 8%, OR (95% CI)=4.76 (1.41-16.67), p=0.012). On aggregate, there was no change in median HR over time. In the interventions associated with apnoea, HR dropped by 38bpm [median (IQR) at time of facemask application: 134bpm (134-150) vs 96bpm (94-102) 20 s after application; p=0.25] and recovered within 30 s. CONCLUSIONS: Facemask applications in term and late-preterm infants during neonatal stabilisation are associated with apnoea and this effect is more pronounced after the first compared with subsequent applications. Healthcare providers should be aware of the TCR and vigilant when applying a face mask to newborn infants. TRIAL REGISTRATION NUMBER: ACTRN12616000768493.


Assuntos
Apneia/etiologia , Bradicardia/etiologia , Máscaras/efeitos adversos , Reflexo Trigêmino-Cardíaco/fisiologia , Apneia/fisiopatologia , Bradicardia/fisiopatologia , Feminino , Idade Gestacional , Frequência Cardíaca , Humanos , Recém-Nascido , Recém-Nascido Prematuro/fisiologia , Masculino , Estudos Prospectivos , Gravação de Videoteipe
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...